Fixed gas detector IGM-13M
Reliable.
Sustainable.
General-purpose.
Features
(option)
Functionality
IGM-13M allows automatic continuous monitoring of dangerous concentrations of combustible, toxic gases, oxygen and carbon dioxide, LOC of hydrocarbon gases in hazardous areas. Due to its high immunity to climatic and mechanical influences, IGM-13M can be installed both indoors and outdoors fields.
Application Scope
- Oil and gas fields
- Oil and gas refineries
- Oil and gas storage facilities
- Chemical manufactures
- Industrial work area
- Pumping stations
- Compressor stations etc.
IGM-13M comes in two types of housing:
Marking:
IGM-13M-1A — aluminium
IGM-13M-1C — stainless steel
1 — XD-IL or XD-SIL housing depending on the material
A — aluminium
C — stainless steel
Marking:
IGM-13M-3A – aluminium
3 — ВАД-РСП-0-D housing
A — aluminium
UP TO 122 GASES AND VAPOURS MEASURING
Depending on the target gas one of the following gas sensors can be installed in IGM-13M:
- Toxic sensor
- Oxygen
- Carbon oxide
- Hydrogen sulphide
- Chlorine
- Hydrogen cyanide
- Ammonia
- Sulphur dioxide
- Nitrogen oxide
- Nitrogen dioxide
- Hydrogen
- Fluorine
- Arsine
- Phosphine
- Monosilane
- Hydrogen peroxide
- Hydrogen fluoride
- Carbonyl chloride
- Methylmercaptan
- Ozone
- Bromine
- Formaldehyde
- Ethyl mercaptan
- Ethylene oxide
- Ethylene
- Methanol
- Ethanol
- Optical sensor
- Carbon dioxide
- Propane
- Methane
- Ethane
- N-Hexane
- N-Butane
- Isobutane
- Pentane
- Propylene
- Methanol
- Toluene
- Ethylene oxide
- Benzene
- Acetone
- Ethylene
- N-octane
- Ethanol
- Methyl tertiary butyl ether
- n-Heptane
- Nonane
- Dekane
- Styrene
- Ethyl acetate
- Automobile gasoline
- Diesel fuelKerosene
- White spirit
- Jet fuel
- Aviation gasoline
- Gasoline 1-butene
- Cyclopentane
- Cyclohexane
- i-butylene
- i-propene
- Ethylbenzene
- Butyl acetate
- 1,3-butadiene (divinyl)
- 1,2-dichloroethane
- Dimethyl sulfide
- 1-hexen
- 1-butanol
- Vinyl chloride
- Cyclopropane
- Diethyl ether
- Propylene oxide
- Chlorobenzene
- 2-methyl-2-propanol
- 2-butanone
- Petroleum product vapors
- Hydrocarbons sum
- PID
- Benzene
- Acetic acid
- 2-Methylpropene (isobutylene)
- Methylbenzene (toluene)
- o-Xylene (dimethylbenzene)
- Arsin
- Phosphine
- Naphthalene
- Trichloroethylene
- Ethane
- Propane
- n-Hexane
- n-butane
- Isobutane
- Pentane
- Propylene
- Methanol
- Ethylene oxide
- Acetone
- Ethylene
- Octane
- Phenol
- n-Heptane
- Ethyl acetate
- Automobile gasoline (isobutylene)
- Diesel fuel (isobutylene)
- Kerosene (on the isobutylene)
- White spirit (for isobutylene)
- n-Butanol
- Propanol
- Ethylbenzene
- Styrene
- Nitrogen oxide
- Methylmercaptan
- Vinyl chloride
- n-propyl
- Acetate
- Epichlorohydrin
- N,N-dimethylacetamide (morpholine)
- Benzyl Chloride
- Furfuryl alcohol
- Ethanol
- 2-aminoethanol
- Diethylamine
- Ethyl chloroformate
- Toluene
- Monoethanolamine
CONTENTS OF DELIVERY
- IGM-13M gas detector
- Validation test certificate
- EX-proof cable gland
- Calibration cap
- EX-proof end plug
- Magnetic key
- Software for calibration and tuning
- Мaintenance documentation
Design Specifics
-60 °C … +60 °C
80-120 kPa
(w/o condensation)
188х145х110 mm
Velan housing
198х136х137 мм
Limatherm housing
< 2,5 kg
aluminium housing
< 3,5 kg
stainless steel housing
GENERAL SPECIFICATION |
|
EX-marking | 1Ex d ia IIC T6 X |
Sensor types | – optical – toxic – PID |
Validation period: | |
– optical sensor | 2 years |
– toxic and PID | 1 year |
Housing variants | – with 2 cable glands (Painted Al, AISI 316) – with 3 cable glands (Painted Al) |
Protection | IP 68 |
Supply voltage | 12-32 VDC |
Power consumption | < 0,7 W |
Adjustment interfaces | – magnetic keys – RS-485 – HART |
MTBF: | |
– optical sensor | 60 000 hours |
– toxic and PID | 30 000 hours |
Average lifetime | 10 years |
OUTPUT INTERFACES |
|
Current loop: | |
– max load | 500 Ohm |
– max voltage (passive mode) | 32 VDC |
HART | |
– HART protocol version | rev.6 (with previous rev support) |
RS-485 | |
– max devices number on single line | up to 256 |
– max voltage (between A and B lines and between signal lines and interface ground) | ± 12 VDC |
Relays | |
– max supply voltage, DC | 60 V |
– max current, DC | 2 А |
– max supply voltage, AC | 250 V |
– max current, AC | 2 А |
Technical documentation and certificates
Documentation: