Control gas detecting system EMI-M1

Control gas detecting system EMI-M1

Variable: certificated with different types of control units and various manufacturers’ gas detectors

The system’s control unit can be used as HART-communicator*

Up to 32 gas detectors connected to the system

Customized at your request

Features

EMI SSD-M1 CONTROL UNIT CAN BE USED AS HART-COMMUNICATOR
for tuning via Software*
CONTROL UNIT VARIABILITY
depending on the issues
MATCH-ALL COMMUNICATIONS PROTOCOLS
operation within other manufacturers’ systems
EASY CALIBRATION AND TUNING
due to the Software
WIRELESS BLUETOOTH CONNECTION
for system tuning and control
DATA TRANSMISSION
via LoRaWAN channel*
THE SYSTEM CAN BE USED AS PART OF EMERGENCY SHUTDOWN SYSTEM
DATA ARCHIVING ON THE SD CARD*
(SD-slot supporting up to 32 Gb)
AUDIO AND/OR LIGHT ALARM
in case of set threshold exceeding
POWER CIRCUIT PROTECTION*

*FOR CONTROL UNIT EMI-SSD-M1

Functionality

  • Automatic continuous monitoring of working zone gas pollution, outdoor facilities and open spaces of industrial facilities
  • Processing and storage of received data
  • Data transfer to control device
  • External circuits switching
  • Audio and light alarm in case of set threshold exceeding

Central devices types

1 EMI – SSD – M1 2 МВ 210-101 3 МВ 110
EMI – SSD – M1
EMI – SSD – M1
Input and output signals specification
Number of measuring channels:
– analog 4-20 mA8
– digital HART8
– digital RS-4851
Number of gas detectors per channel:
– analog 4-20 mA1
– digital HART1
– digital RS-485< 32
Output channels type (number):
– digitalRS-485 (1 channel)*
– analogdiscreet relays outputs (3 relays)
– radiochannels**– Bluetooth (1 channel)
– LoRaWAN (1 channel)
Power supply parameters
Supply voltage12-32 VDC (nominal 24 VDC)
Power consumption< 2,5 W
Max. supply power8 gas detectors with sensor heating < 120W
Reading value types
Audio alarmpresent
Visual display– OLED displaying information on measured concentrations and modes
– 2 general condition LEDs
Design specifications
Overall dimensions (LxWxH), mm(180×70×100) ±1
Weight, kg< 0,5
ProtectionIP 20
Operation parameters
Temperature range, ⁰С-10…50
RH range, %< 95 (w/o condensation)
Pressure range, kPa80…120
Appendix:
* type of the channel is chosen by the user via the control unit’s menu
** option

Technical documentation and certificates

Analog input module МВ 210-101 (LLC «Oven»)
Analog input module МВ 210-101 (LLC «Oven»)
Input and output signals specification
Number of measuring channels:
– analog 4-20 mA8
– digital HART
– digital RS-485
Number of gas detectors per channel:
– analog 4-20 mA1
– digital HART
– digital RS-485
Output channels type (number)digital: Ethernet (2 channels)
Power supply parameters
Supply voltage10-48 VDC (nominal 24 VDC)
Power consumption< 4 W
Max. supply powernot provided
Reading value types
Audio alarmnot present
Visual display– channel operating mode LED (1 for each channel)
– control unit operating mode LED
Design specifications
Overall dimensions (LxWxH), mm(123×83×42) ±1
Weight, kg< 0,4
ProtectionIP 20
Operation parameters
Temperature range, ⁰С-40…+55
RH range, %10…95 (w/o condensation)
Pressure range, kPa80-120
Analog input module МВ 110 (LLC «Oven»)
Analog input module МВ 110 (LLC «Oven»)
Number of measuring channels
224.2А224.8А
Number of measuring channels:
– analog 4-20 mA28
– digital HART
– digital RS-485
Number of gas detectors per channel:
– analog 4-20 mA11
– digital HART
– digital RS-485
Output channels type (number)digital: RS-485 (1 channel)
Power supply parameters
Supply voltage~90…264 VAC (nominal ~230) at a frequency of 47…63 Hz
=18…30 VDC (nominal =24)
Power consumption< 6 W
Max. supply powernot provided
Reading value types
Audio alarmnot present
Visual display– сhannel operating mode LED (1 for each channel)
– control unit operating mode LED
Design specifications
Overall dimensions (LxWxH), mm(63×110×75) ±1
Weight, kg< 0,5
ProtectionIP 20
Operation parameters
Temperature range, ⁰С-10…+55
RH range, %< 80
Pressure range, kPa80-120

Gas detectors

IGM-10
IGM-10
IGM-12M
IGM-12M
IGM-13M
IGM-13M
Various manufacturers’ gas detectors
Various manufacturers’ gas detectors

UP TO 122 GASES AND VAPOURS MEASURING

Toxic sensor
  • Oxygen
  • Carbon oxide
  • Hydrogen sulphide
  • Chlorine
  • Hydrogen cyanide
  • Ammonia
  • Sulphur dioxide
  • Nitrogen oxide
  • Nitrogen dioxide
  • Hydrogen
  • Fluorine
  • Arsine
  • Phosphine

 

  • Monosilane
  • Hydrogen peroxide
  • Hydrogen fluoride
  • Carbonyl chloride
  • Methylmercaptan
  • Ozone
  • Bromine
  • Formaldehyde
  • Ethyl mercaptan
  • Ethylene oxide
  • Ethylene
  • Methanol
  • Ethanol
Optical sensor
  • Carbon dioxide
  • Propane
  • Methane
  • Ethane
  • N-Hexane
  • N-Butane
  • Isobutane
  • Pentane
  • Propylene
  • Methanol
  • Toluene
  • Ethylene oxide
  • Benzene
  • Acetone
  • Ethylene
  • N-octane
  • Ethanol
  • Methyl tertiary butyl ether
  • n-Heptane
  • Nonane
  • Dekane
  • Styrene
  • Ethyl acetate
  • Automobile gasoline
  • Diesel fuelKerosene

 

  • White spirit
  • Jet fuel
  • Aviation gasoline
  • Gasoline 1-butene
  • Cyclopentane
  • Cyclohexane
  • i-butylene
  • i-propene
  • Ethylbenzene
  • Butyl acetate
  • 1,3-butadiene (divinyl)
  • 1,2-dichloroethane
  • Dimethyl sulfide
  • 1-hexen
  • 1-butanol
  • Vinyl chloride
  • Cyclopropane
  • Diethyl ether
  • Propylene oxide
  • Chlorobenzene
  • 2-methyl-2-propanol
  • 2-butanone
  • Petroleum product vapors
  • Hydrocarbons sum
PID
  • Benzene
  • Acetic acid
  • 2-Methylpropene (isobutylene)
  • Methylbenzene (toluene)
  • o-Xylene (dimethylbenzene)
  • Arsin
  • Phosphine
  • Naphthalene
  • Trichloroethylene
  • Ethane
  • Propane
  • n-Hexane
  • n-butane
  • Isobutane
  • Pentane
  • Propylene
  • Methanol
  • Ethylene oxide
  • Acetone
  • Ethylene
  • Octane
  • Phenol
  • n-Heptane
  • Ethyl acetate

 

  • Automobile gasoline (isobutylene)
  • Diesel fuel (isobutylene)
  • Kerosene (on the isobutylene)
  • White spirit (for isobutylene)
  • n-Butanol
  • Propanol
  • Ethylbenzene
  • Styrene
  • Nitrogen oxide
  • Methylmercaptan
  • Vinyl chloride
  • n-propyl
  • Acetate
  • Epichlorohydrin
  • N,N-dimethylacetamide (morpholine)
  • Benzyl Chloride
  • Furfuryl alcohol
  • Ethanol
  • 2-aminoethanol
  • Diethylamine
  • Ethyl chloroformate
  • Toluene
  • Monoethanolamine

Control unit EMI-SSD-M1 functionality

Control unit EMI-SSD-M1 is a MLC (multiple-line controller) enabled to connect 8 sensors via the analogue interface «current loop» and the HART protocol or 32 sensors via the RS-485 interface; as well as data transfer to the controller interface selection: RS-485, LoRaWAN, Bluetooth.

Control unit EMI-SSD-M1 functionality
Temperature range
Temperature range

-10 °C … +50 °C

Pressure range
Pressure range

80-120 kPa

RH range
RH range

15-95%
(w/o condensation)

Overall dimensions (LxWxH)
Overall dimensions (LxWxH)

180х60х100 mm

Weight
Weight

0,5 kg