Variable: certificated with different types of control units and various manufacturers’ gas detectors
The system’s control unit can be used as HART-communicator*
Up to 32 gas detectors connected to the system
Customized at your request
Features
EMI SSD-M1 CONTROL UNIT CAN BE USED AS HART-COMMUNICATOR
for tuning via Software*
CONTROL UNIT VARIABILITY
depending on the issues
MATCH-ALL COMMUNICATIONS PROTOCOLS
operation within other manufacturers’ systems
EASY CALIBRATION AND TUNING
due to the Software
WIRELESS BLUETOOTH CONNECTION
for system tuning and control
DATA TRANSMISSION
via LoRaWAN channel*
THE SYSTEM CAN BE USED AS PART OF EMERGENCY SHUTDOWN SYSTEM
DATA ARCHIVING ON THE SD CARD*
(SD-slot supporting up to 32 Gb)
AUDIO AND/OR LIGHT ALARM
in case of set threshold exceeding
POWER CIRCUIT PROTECTION*
*FOR CONTROL UNIT EMI-SSD-M1
Functionality
- Automatic continuous monitoring of working zone gas pollution, outdoor facilities and open spaces of industrial facilities
- Processing and storage of received data
- Data transfer to control device
- External circuits switching
- Audio and light alarm in case of set threshold exceeding
Central devices types
1
EMI – SSD – M1
2
МВ 210-101
3
МВ 110
EMI – SSD – M1
Input and output signals specification |
|
Number of measuring channels: | |
– analog 4-20 mA | 8 |
– digital HART | 8 |
– digital RS-485 | 1 |
Number of gas detectors per channel: | |
– analog 4-20 mA | 1 |
– digital HART | 1 |
– digital RS-485 | < 32 |
Output channels type (number): | |
– digital | RS-485 (1 channel)* |
– analog | discreet relays outputs (3 relays) |
– radiochannels** | – Bluetooth (1 channel) – LoRaWAN (1 channel) |
Power supply parameters |
|
Supply voltage | 12-32 VDC (nominal 24 VDC) |
Power consumption | < 2,5 W |
Max. supply power | 8 gas detectors with sensor heating < 120W |
Reading value types |
|
Audio alarm | present |
Visual display | – OLED displaying information on measured concentrations and modes – 2 general condition LEDs |
Design specifications |
|
Overall dimensions (LxWxH), mm | (180×70×100) ±1 |
Weight, kg | < 0,5 |
Protection | IP 20 |
Operation parameters |
|
Temperature range, ⁰С | -10…50 |
RH range, % | < 95 (w/o condensation) |
Pressure range, kPa | 80…120 |
Appendix: | |
* type of the channel is chosen by the user via the control unit’s menu ** option |
Technical documentation and certificates
Certificates
Analog input module МВ 210-101 (LLC «Oven»)
Input and output signals specification |
|
Number of measuring channels: |
|
– analog 4-20 mA | 8 |
– digital HART | – |
– digital RS-485 | – |
Number of gas detectors per channel: | |
– analog 4-20 mA | 1 |
– digital HART | – |
– digital RS-485 | – |
Output channels type (number) | digital: Ethernet (2 channels) |
Power supply parameters |
|
Supply voltage | 10-48 VDC (nominal 24 VDC) |
Power consumption | < 4 W |
Max. supply power | not provided |
Reading value types |
|
Audio alarm | not present |
Visual display | – channel operating mode LED (1 for each channel) – control unit operating mode LED |
Design specifications |
|
Overall dimensions (LxWxH), mm | (123×83×42) ±1 |
Weight, kg | < 0,4 |
Protection | IP 20 |
Operation parameters |
|
Temperature range, ⁰С | -40…+55 |
RH range, % | 10…95 (w/o condensation) |
Pressure range, kPa | 80-120 |
Analog input module МВ 110 (LLC «Oven»)
Number of measuring channels |
||
224.2А | 224.8А | |
Number of measuring channels: | ||
– analog 4-20 mA | 2 | 8 |
– digital HART | – | – |
– digital RS-485 | – | – |
Number of gas detectors per channel: | ||
– analog 4-20 mA | 1 | 1 |
– digital HART | – | – |
– digital RS-485 | – | – |
Output channels type (number) | digital: RS-485 (1 channel) | |
Power supply parameters |
||
Supply voltage | ~90…264 VAC (nominal ~230) at a frequency of 47…63 Hz =18…30 VDC (nominal =24) |
|
Power consumption | < 6 W | |
Max. supply power | not provided | |
Reading value types |
||
Audio alarm | not present | |
Visual display | – сhannel operating mode LED (1 for each channel) – control unit operating mode LED |
|
Design specifications |
||
Overall dimensions (LxWxH), mm | (63×110×75) ±1 | |
Weight, kg | < 0,5 | |
Protection | IP 20 | |
Operation parameters |
||
Temperature range, ⁰С | -10…+55 | |
RH range, % | < 80 | |
Pressure range, kPa | 80-120 |
UP TO 122 GASES AND VAPOURS MEASURING
- Toxic sensor
- Oxygen
- Carbon oxide
- Hydrogen sulphide
- Chlorine
- Hydrogen cyanide
- Ammonia
- Sulphur dioxide
- Nitrogen oxide
- Nitrogen dioxide
- Hydrogen
- Fluorine
- Arsine
- Phosphine
- Monosilane
- Hydrogen peroxide
- Hydrogen fluoride
- Carbonyl chloride
- Methylmercaptan
- Ozone
- Bromine
- Formaldehyde
- Ethyl mercaptan
- Ethylene oxide
- Ethylene
- Methanol
- Ethanol
- Optical sensor
- Carbon dioxide
- Propane
- Methane
- Ethane
- N-Hexane
- N-Butane
- Isobutane
- Pentane
- Propylene
- Methanol
- Toluene
- Ethylene oxide
- Benzene
- Acetone
- Ethylene
- N-octane
- Ethanol
- Methyl tertiary butyl ether
- n-Heptane
- Nonane
- Dekane
- Styrene
- Ethyl acetate
- Automobile gasoline
- Diesel fuelKerosene
- White spirit
- Jet fuel
- Aviation gasoline
- Gasoline 1-butene
- Cyclopentane
- Cyclohexane
- i-butylene
- i-propene
- Ethylbenzene
- Butyl acetate
- 1,3-butadiene (divinyl)
- 1,2-dichloroethane
- Dimethyl sulfide
- 1-hexen
- 1-butanol
- Vinyl chloride
- Cyclopropane
- Diethyl ether
- Propylene oxide
- Chlorobenzene
- 2-methyl-2-propanol
- 2-butanone
- Petroleum product vapors
- Hydrocarbons sum
- PID
- Benzene
- Acetic acid
- 2-Methylpropene (isobutylene)
- Methylbenzene (toluene)
- o-Xylene (dimethylbenzene)
- Arsin
- Phosphine
- Naphthalene
- Trichloroethylene
- Ethane
- Propane
- n-Hexane
- n-butane
- Isobutane
- Pentane
- Propylene
- Methanol
- Ethylene oxide
- Acetone
- Ethylene
- Octane
- Phenol
- n-Heptane
- Ethyl acetate
- Automobile gasoline (isobutylene)
- Diesel fuel (isobutylene)
- Kerosene (on the isobutylene)
- White spirit (for isobutylene)
- n-Butanol
- Propanol
- Ethylbenzene
- Styrene
- Nitrogen oxide
- Methylmercaptan
- Vinyl chloride
- n-propyl
- Acetate
- Epichlorohydrin
- N,N-dimethylacetamide (morpholine)
- Benzyl Chloride
- Furfuryl alcohol
- Ethanol
- 2-aminoethanol
- Diethylamine
- Ethyl chloroformate
- Toluene
- Monoethanolamine
Control unit EMI-SSD-M1 functionality
Control unit EMI-SSD-M1 is a MLC (multiple-line controller) enabled to connect 8 sensors via the analogue interface «current loop» and the HART protocol or 32 sensors via the RS-485 interface; as well as data transfer to the controller interface selection: RS-485, LoRaWAN, Bluetooth.
Temperature range
-10 °C … +50 °C
Pressure range
80-120 kPa
RH range
15-95%
(w/o condensation)
Overall dimensions (LxWxH)
180х60х100 mm