Portable gas detector Microsense M3
with a possibility to install a PID sensor
Multipurpose: up to 100 gases and vapors measuring
Up to 100 hours of Operating time without recharging
Features
Functionality
Detectors can be used in coal, oil, gas and power industry.
PID is intended for measuring LOC of hydrocarbons, Arsine and Phosphine concentrations.
Optical sensors are intended for measuring LEL of hydrocarbons (CH4, C3H8, C2H2) and Carbon dioxide (CO2).
Toxic sensors are intended for measuring toxic gases concentrations (H2S, CO, CL2, NH3, SO2, NO, NO2, H2, F2, O3, Br2, HP, HCL, PH3, SiH4, AsH3) and oxygen (O2) volume per cent.
Application Scope
- hazardous areas zones 0, 1 and 2
- underground mines and quarries, including gas and dust hazardous ones
- explosives mixtures categories IIA, IIB and IIC
UP TO 100 GASES AND VAPORS MEASURING
ppm to mg/m3 software switching
- Optical sensors
- Hydrocarbons (C1-C10)
- Carbon dioxide
- Benzene
- Diesel fuel
- Kerosene
- White spirit
- Ethylene
- Propylene
- Ethylene oxide
- Benzene
- Toluene
- Ethanol
- Methanol
- Acetone
- Methyl tertiary butyl ether
- Styrene
- Ethyl acetate
- Toxic Sensors
- Oxygen
- Carbon oxide
- Hydrogen sulphide
- Ammonia
- Sulphur oxide and dioxide
- Nitrogen oxide and dioxide
- Hydrogen
- Hydrogen fluoride
- Mercaptans
- Formaldehyde
- Hydrogen peroxide
- Ozone
- Bromine
- Carbonyl chloride
- Phosphine
- Monosilane
- PID
- Isobutylene
- Benzene
- Toluene
- Phenol
- Ethane-Dekane
- O-Xylene
- Methanol
- Acetone
- Mercaptans
- Styrene
- Ethylene
- Propylene
- Arsin Ethylene oxide
- Nitrogen oxide
- Ethylbenzene
Contents of delivery
- Gas detector
- Battery charger
- Docking station
- Calibration cap
- Validation test certificate
- Software for calibration and tuning
- Maintenance documentation
Additionally: protective case, external sampler
Functionality
SPECIFICS
-40 °C … +60 °C
80-120 kPa
20-95%
(w/o condensation)
115x70x35 mm
0,25 kg
SENSORS CONFIGURATION
GENERAL SPECIFICATION |
|
Sampling method | – diffusion – forced (option) |
Sensor types | – optical – toxic – PID |
Target components: | |
– optical | combustible hydrocarbon gases |
– toxic | toxic gases, H2, O2 |
– PID | LOC of hydrocarbon and toxic gases |
Number of target gases | 1-5 (depending on the modification) |
Output signals | – color graphics LCD – USB for readings – buzzer – vibration – alarm LEDs |
Sound-pressure level | > 90 dB |
Operation time from the battery (under normal conditions): | |
– w/o PID | > 100 hours |
– with PID | > 8 hours |
EX-marking | Р0 Ex ia I Х /0 Ex ia IIС T4 Х |
Protection | IP 68 |
Non-volatile memory | 120 000 events |
Validation period | 1 year |
MTBF | 10 000 hours |
Average lifetime | 10 years |