Fixed gas detector IGM-10
Simple.
Reliable.
Low-maintenance.
Features
											THE LOWEST POWER CONSUMPTION IN THE LINEUP										
																					
												>0,5 W (alarm mode)
>0,25 W (standby mode)
																			>0,25 W (standby mode)
											DESIGN FLEXIBILITY										
																					
												Wired/built-in battery supply
(depending on the modification)
																			(depending on the modification)
											SMALL SIZE AND WEIGHT										
																					
												compared with the analogues											
																			
											2 YEARS										
																					
												validation period for optical sensors											
																			
											HIGH PRECISION										
																					
												3% LEL accuracy											
																			 
						
											SHORT RESPONSE TIME										
																					
												Т0,9 5 seconds for light hydrocarbon gases (methane)											
																			
											IMMUNITY TO 99%RH										
																					
												for models with optical sensor (option)											
																			
											LOW PRICE										
																			
											VIBRATION RESISTANCE										
																					
												seismic resistance certificate											
																			
											IMMUNITY TO ELECTRO-MAGNETIC RADIATION										
																					
												< 3 W/m											
																			Functionality
IGM-10 allows automatic continuous monitoring of dangerous concentrations of combustible gases (methane, propane, hexane, etc.) and carbon dioxide in hazardous areas. Due to its high immunity to climatic and mechanical influences, IGM-10 can be installed both indoors and outdoors fields.
Application Scope
- Gas and oil field, refineries and storage facilities;
- Chemical industries;
- Industrial work area;
- Pumping stations;
- Compressor stations etc.
Types and specifications
														
															
									
									
										
											1										
										
											IGM-10-X-11										
									
									
								
									
									
										
											2										
										
											IGM-10(IR/Tox)-XX-Y										
									
									
																					
					
														IGM-10-X-11													
													(wired supply)
with an optical sensor
| GENERAL SPECIFICATION | |
| Measuring method | optical | 
| Sampling method | diffusive | 
| Validation period | 2 years | 
| EX-marking: | 1Ex d ia IIC T6 X | 
| Supply voltage | 12-28 VDC | 
| Power consumption | 0,5 W | 
| Ambient temperature | от -40... +60⁰C | 
| Relative humidity (w/o condensation) | < 98% | 
| Output signals | - Current loop (passive) - RS-485 - 2 transistors (engaged on the scheme with common emitter) for set alarm level of target gas - Light indication | 
| MTBF | 100 000 hours | 
| Protection | IP67 | 
| Housing material | aluminium | 
| Average lifetime | 10 years | 
Technical documentation and certificates
IGM-10-X-11 (wired supply)
Documentation:
Software
														IGM-10(IR/Tox)-XX-Y 													
													(self-contained battery power supply)
optical or toxic sensor can be installed
| GENERAL SPECIFICATION | |
| Measuring method | - optical - toxic | 
| Sampling method | diffusive | 
| Validation period | |
| - optical sensor | 2 years | 
| - toxic and PID | 1 year | 
| EX-marking | 1Ex d ia IIC T6 X | 
| Supply voltage | 3,0-3,6 VDC | 
| Power consumption | 0,05 W | 
| Operating time from a battery, minimum Battery is to be replaced | 1 year | 
| Battery type | lithium-ion D – ER34615 | 
| Ambient temperature | от -10... +40⁰С (CO2, optical sensor) от -10... +60⁰С (combustible gases/hydrocarbons, optical sensor) от -30... +50⁰С (toxic sensor) от -40... +60⁰С (combustible gases/hydrocarbons, optical sensor) от -60... +60⁰С (combustible gases/hydrocarbons, optical sensor) | 
| RH (w/o condensation) | < 95% | 
| Output signals | - Current loop (passive) - RS-485 - 2 transistors (engaged on the scheme with common emitter) for set limit level of target gas alarm due to the data level | 
| MTBF: | |
| - optical sensor | 60 000 hours | 
| - toxic | 30 000 hours | 
| Protection | IP67 | 
| Housing material | aluminium | 
| Average lifetime | 10 years | 
Technical documentation and certificates
IGM-10(IR/Tox)-XX-Y (self-contained battery power supply)
Target gases and marking when ordering
Wired supply
- Optical sensors (IGM-10-X-XX)
- IGM-10-1-11 Methane (CH4)
- IGM-10-2-11 Propane (C3H8)
 
Battery supply
- Optical sensors (IGM-10IR)
- IGM-10IR-01-Y (-T) Methane (CH4)
- IGM-10IR-02-Y (-T) Propane (C3H8)
- IGM-10IR-03-Y (-T) N-Hexane (C6H14)
- IGM-10IR-04-Y (-T) Carbon Dioxide (CO2)
 
- Toxic sensors
- IGM-10Tox-01-Y (-T) Oxygen O2
- IGM-10Tox-02-Y (-T) Carbon Oxide CO
- IGM-10Tox-03-Y (-T) Hydrogen sulphide H2S
- IGM-10Tox-04-Y (-T) Hydrogen sulphide high concentration
- IGM-10Tox-05-Y (-T) Sulphur dioxide SO2
- IGM-10Tox-06-Y (-T) Sulphur dioxide high concentration
- IGM-10Tox-07-Y (-T) Nitrogen oxide NO
- IGM-10Tox-08-Y (-T) Nitrogen dioxide NO2
- IGM-10Tox-09-Y (-T) Ammonia NH3
- IGM-10Tox-10-Y (-T) Ammonia high concentration NH3
- IGM-10Tox-11-Y (-T) Hydrogen (H2)
- IGM-10Tox-12-Y (-T) Hydrogen cyanide (HCN)
- IGM-10Tox-13-Y (-T) Methanol (CH3OH)
- IGM-10Tox-14-Y (-T) Ethanol (C2H5OH)
- IGM-10Tox-15-Y (-T) Hydrogen fluoride (HF)
 
CONTENTS OF DELIVERY
 
						- IGM-10
- Validation test certificate
- Magnetic key
- Software for calibration and tuning
- Maintenance documentation
- Datasheet
- Calibration cap
Design specifics
 
						 
										
										Pressure range									
									80-120 kPa
 
										
										RH range (w/o condensation)									
									< 98%
 
										
										Overall dimensions (LxWxH)									
									124х155х91 mm
Battery supply
 
										
										Overall dimensions (LxWxH)									
									124х146х91 mm
Wired supply
 
										
										Weight									
									< 1,5 kg
Self-contained power supply IGM-10 modification specifics
														BUILT-IN BATTERY POWER SUPPLY													
													
														one battery operates at least one year													
												
														EASY BATTERY REPLACEMENT													
													
														after one year of running													
												
														MOUNTING IN HARD-TO-REACH PLACES													
													
														can be used in wireless and independent systems													
												
														INTRINSICALLY SAFE CIRCUIT													
													
														allows servicing in hazardous areas													
												
														RIG-UP TIME REDUCTION													
													
														due to cable lines absence													
												
														COMPARTIBLE WITH WIRELESS SYSTEMS													
													
														Emerson, Endress-Hauser etc.													
												
														SUBSTANTIAL SAVING													
													
														engineering costs reduction													
												